My home is equipped with electric membrane heating. The company is Zhonghui Geothermal. In July 2006, it was well established. It was officially used on December 10th to give you an introduction to the installation and use of the experience. You are interested in warming the bobbin. You are not a childcare person. I am a northerner and have not been accustomed to winter in the south. The cold weather, so it has been looking for the right heating method, willing to come to my home to visit the field can also contact me, no problem.
The comparison between plumbing and electric heating was started. I used an independent heating boiler in the north. It was very warm and convenient. The cost was not expensive. The gas fee for a heating season was less than RMB 1600, but I was at the time. One person lived, opened to 10 degrees during the day, and returned to 18 degrees in the evening, so it was more economical, but there was a big difference between the north and the south. Although the absolute weather in the north was lower than in the south, the northern building was insulated, and the windows were It is double-glazed, and every family is heated. The entire building is heated evenly, so there is little heat loss, and the south cannot have these advantages. If a unit is hot for your home, it is equal to the wall that you have given to your neighbors. The loss is greater.
1. After considering the installation cost again, it was decided to use electric heating. Because the initial construction cost of the plumbing is relatively high, the thickness of the water pipes accounts for more layers, and the boilers generally have to be replaced in about 5 years. Natural gas in Shanghai is not cheap. My home is a small three-bedroom house of 100 square meters, and the lowest price for plumbing is 16,000 yuan. Boilers are not the best brands, if the famous brands will be around 20,000 yuan. My home height is not high, and if I add water pipes, etc., I must take up 10~12CM, which is too low. Even if it is used economically, it is estimated that the monthly gas fee should also be around 1,000 yuan, and the boiler cannot be stopped once it is started, because extreme cold temperatures can damage the boiler water pipes. In addition, hard water in China's water supply can cause scale, which may cause long-term boiler safety hazards. In addition, although Zhonghui Company is not a unique company, the overall service quality is also acceptable. Their Chief Zhang Gong personally went to the site to guide the installation. He was very kind.
The advantage of electrothermal membrane heating is that the initial cost is low. My family calculates about 70 square meters according to the area within the suite, 148 yuan per square meter, plus 5 to 6 thermostats, a total of 11,700 yuan, and no other installation costs. The floor height is about 8CM, and the temperature rises quickly. Basically, it takes about half an hour to feel the floor heat, and you want to shut it off. It is not limited by equipment. The electricity bill is time-sharing. I usually open it after 10pm. Higher temperature, this is half the cost savings. Considering that Shanghai's winter is not very long, the electric warmer switches freely, warms up fast, and has certain flexibility.
2. Cost of use My family set the temperature is: bedroom 18 degrees, the living room 17 degrees hall 16 degrees, North House and a small study did not open because of the small area of ​​low power and low usage. Usually nobody is set at home until 14-15 degrees. Now when the valley consumes 30 to 35 degrees of electricity every day, when the trough consumes 15 to 20 degrees, the basic daily cost is about 20 to 25 yuan. The weather in these two days is warm, and it is 15 yuan per day. In a sentence, my family is living on the 13th floor, belonging to the "cold zone", huh, huh
3. Other conditions Room temperature maintenance and energy consumption vary greatly from one family to another. Like my home, in the renovation, I replaced all the single-layer glass with poor KFS quality and replaced it with a double-glazed glass of a joint venture brand, which is dust-proof, cold-proof and heat-insulating. The disadvantage of my family is that the doors are few and large. Because of the open design, so the energy loss is quite large, I installed some thick curtains, especially the North House, so keep warm. My family is installing Fillinger reinforced composite geothermal flooring, which has good heat transfer. Basically, after 20 minutes, the temperature of the soles of the feet was felt. Within about 1 to 2 hours, the temperature in the room rose to the set temperature.
4. Precautions Pay attention to the capacitance of your home and do not overload. My home design is 7000W, the capacitance is 40A and 8800W, I actually opened 5000W, there is no problem with capacity. However, my family still burned an insurance. It turned out that when the KFS was first installed, the fuse was disconnected, and the screw was not tightened. As a result, the spark plug burned the wire and the fuse box. After I changed it, there was no problem. So you have to check the installation of the circuit, especially the details of the installation, after all, the power and instantaneous current is very large, will take the problem out of failure. However, it is no problem to pick it up.
Now my family is very comfortable in winter. We can wear a thin sweater and stay at home without slippers. We can even wear only one shirt when we drive high, but it is not necessary to use electricity after all. My 2-year-old son It is not necessary to have three layers of three layers outside in winter. It has also been playing on the floor with bare feet. The overall feeling is good.