SZB water ring vacuum pump installation instructions Equipment to be installed according to Figure 3 1. Vacuum pump used for water diversion pump, the installation location and the distance between the pump to be more spacious, so pump and vacuum pump for easy maintenance. 2. Vacuum pump suction pipe can not be leaky phenomenon. The foundation size of the installation plan or in-kind measurement of the formula. 3. Vacuum pump shaft and motor shaft to be kept level, do not allow a different heart phenomenon. The foundation must be solid and reliable. After pouring cement, dry to 48 hours, re-check the installation for any change, and then tighten the foot bolts can not be loose.
Hengshi Diamond Tools CO.,LTD , https://www.ryomaltools.com