There are two types of common faults: one is a high-impedance fault; the other is a low-impedance fault. The so-called high-resistance fault, that is, the cable is blown, the meter measures the resistance, or the insulation decreases between the phases or the ground, but there is a certain resistance; the so-called low-resistance fault, that is, the wire is short-circuited or completely shorted to the ground, the current Increase, the power transmission has a trip phenomenon. These two types of faults and their frequent occurrence pose a threat to the normal use of lawn lights. Therefore, we must pay full attention to the reasons and countermeasures.
The main cause of lawn lamp failure
1. Poor construction quality
The proportion of failures caused by construction quality is large. Main performances: First, the depth of the cable trench is not enough, the sand-covered bricks are not constructed according to the standard; the second is that the production and installation of the aisle tubes do not meet the requirements, the two ends are not made according to the standard; the third is when paving the cable The fourth pre-buried pipe is not constructed according to the standard requirements, mainly because the pre-buried pipe is too thin, plus a certain degree of camber, it is quite difficult to wear the cable, and there is a "dead bend" at the bottom of the foundation; The wire nose crimping and insulation wrap are not thick enough, and after a long period of operation, the phases are short-circuited.
2, the material is not off
Judging from the fault conditions handled in recent years, there are also many factors in the low quality of materials. The main performance is: the wire contains less aluminum, the wire is harder, and the insulation layer is thin. This situation has been more common in recent years.
3, the quality of supporting projects is not too hard
Lawn light cables are generally laid on green belts. The construction quality of the sidewalk is poor, the ground sinks, and the cable is deformed by force, resulting in cable armoring. In particular, the northeastern region is in an extremely cold zone, and the arrival of winter makes the cable and the soil form a whole. Once the ground subsides, it will be strained at the bottom of the lawn lamp foundation, and when the rainwater is too much in summer, it will be blown at the base root.
4, the design is not reasonable
On the one hand, it is overloaded. With the continuous development of urban construction, the lawn lamps are also continuously extended. When the lawn lamps are newly built, which lawn lamps are close to each other, which circuit is received, and in recent years, the advertising industry has developed rapidly, and the advertising load is also connected to the lawn. On the lamp, the load of the lawn lamp is too large, the cable is overheated, the wire nose is overheated, the insulation is lowered, and the grounding is short-circuited; on the other hand, the lamp post is designed only considering the condition of the lamp post, ignoring the space of the cable head, After the cable head is wrapped, most of the doors are not closed, sometimes the cable length is not enough, and the joint production does not meet the requirements, which is also a factor causing the failure.
SS Chain Link,Steel Link Chain,Stainless Chain Link,Stainless Steel Link Chain
Jiangsu Hongze Stainless Steel Wire Rope Co., Ltd , https://www.hzrope.com