When the DC system has an abnormal situation, it should be inspected and processed. The following are some common voltage problems that Dalan Motor has compiled.

There are three main solutions to voltage instability:

(1) Magnetic pole gasket: inserting a benign magnetic conductive material under the pole piece of the DC motor to reduce the excitation magnetic field gap, so that the DC motor can saturate the output characteristic at a small excitation current, thereby making the output of the DC motor The voltage is stable.

(2) Connect a suitable resistive load such as an incandescent bulb in parallel with the magnetic field adjusting resistor of the excitation circuit, and use the resistance of the resistive load to become a non-linear resistance characteristic, so that the field resistance line and excitation characteristics start. The segments have a large angle of intersection, resulting in a distinct intersection with the no-load characteristic curve, so that the DC motor will have a stable operating point at lower voltages.

(3) Adopting automatic excitation adjustment device of generator: The automatic excitation adjustment device of generator has good excitation characteristics, and has various adjustment modes such as constant reactive power and constant power factor, which is very effective for improving the stability and transient response capability of the system. At the same time, it can solve the problem of generator reactive power swing caused by unstable DC motor output voltage and system voltage fluctuation.

The DC motor operating voltage is higher than the rated voltage:

A 220V DC motor, when starting, the commutator is ignited and the switch trips. Check the supply voltage is 230V. If the supply voltage exceeds the rated voltage, will this happen? What range should the supply voltage be suitable for?

The starting voltage is too high, because the starting current when starting the motor is already very large, so if the 230V voltage is suddenly activated, sparks and trips will occur, which is normal. After starting, if the stable working voltage is 230V, the motor should be no problem. The key is that the current at startup is too large. It should be possible to solve this problem.

The relationship between voltage and current of DC motor: The voltage, current and power of DC motor has always been a difficult point in the teaching of high school physics "electric power and electric power". Because the motor circuit belongs to the non-pure resistance circuit, Ohm's law is not applicable, and students often do not really understand the use conditions of Ohm's law. They often use Ohm's law to solve the voltage, current and power problems of the DC motor, resulting in such problems. The rate is very high.







----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant

Copyright http: / (Dalan Motor) Reprint, please indicate the source
Http://news.chinawj.com.cn

LPG Mass Flow Meter

Zhejiang Sealand Technology Co., Ltd. is a trustworthy manufacturer of LPG Mass Flow Meter, LPG Mass Flowmeter, LPG Flow Meter, LPG Flowmeter, LPG meter, ATEX, IECEx & CE approved.

Sealand have DN03 to DN150 size meters and are developing bigger models. Each meter can be connected with your computer through a USB-to-RS485 converter. The detail steps are as follows. Connect the meter and computer with a USB-to-RS485 converter( converter A+ end to transmitter A+ end, B- to B-, and GND to GDN); turn to device manager of the computer to check COM port connected with meter. Start the software, select the right COM port and click Connect; do not change any other parameters (if you do not know the right one, click Automatic options on the left, click Connect, plug & unplug the transmitter, and then check if it is connected). You can click Connect on the tool bar to disconnect or connect again. It will shown Connected/Not Connected at the bottom of this interface.

LPG Mass Flow Meter, LPG Mass Flowmeter, LPG Flow Meter, LPG Flowmeter, LPG meter

Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeter.com