Rotary vane pump troubleshooting

Rotary vane pump in operation, if improper operation, often failure, such as decreased vacuum, fuel injection, smoke, oil seal leaks, noise and other conditions, and pump vacuum pump oil emulsification and so on. In case of such a situation, first of all do not panic, so after the shutdown according to the fault one by one excluded. Here are a few ways to troubleshoot. First, the vacuum drop: refers to the current measured vacuum than the factory index or the vacuum when the previous use of low. There are many reasons for the low vacuum level. Here are a few key facts. 1, this time plus the vacuum pump oil grades and the original is not the same. Different vacuum pump oil grades, as different grades of saturated vapor pressure within the oil is not the same, so the result is not the same. Solution: According to the product model specifications to replace the correct new vacuum pump oil. 2, but also due to vacuum pump oil caused by the low vacuum situation, that is, vacuum pump oil emulsification discoloration, or too dirty. The solution: put all the pump vacuum pump oil, replace the same type of vacuum pump oil, and to be pumping gas and water vapor impurities do not enter the pump. 3, was pumping gas temperature may be too high. The solution: to reduce the temperature of the gas being drawn, or you can add a corresponding heat exchanger. 4, the pump is blocked or poor road, the pump cavity does not maintain a certain amount of oil. Solution: check whether the smooth flow of oil, plus the same type of vacuum pump oil. 5, with the gap to change. This is the long-term exhaust gas containing dust, etc., resulting in increased wear between the rotating plate and the stator gap. Solution: check the gap is too large, replace the new parts. Second, noise: Pump noise here. 1, Knocking cylinder, the pump issued an irregular sound operation, like a metal beat metal sound. This is the voice of the vane that hits the pump body. This situation is mainly caused by the spring break between mating rotors or the contraction or ejection failure. The solution: Open the pump to check whether the rotary spring is damaged. Replace the spring. 2, exhaust valve noise, the main exhaust valve is damaged. Solution: a good replacement of the exhaust valve. Third, smoke and fuel injection: refers to the rotary vane pump exhaust smoke or fuel in operation. 1, smoke, if the pump has just begun to run a smoke phenomenon, is normal, if the smoke is not normal for a long time. The solution: smoke shows the pump inlet, including pipes, valves, containers are repaired. Leakage after treatment, the smoke will end. 2, fuel injection, indicating a large number of leaks outside the air inlet, or even the air inlet exposure to the atmosphere. Solution: seal the pump inlet to pump operation, if you do not fuel injection, indicating a leak; exhaust valve damage, check the exhaust valve is damaged, replace the bad exhaust valve.

Institution Chandelier

LAVIUS devotes itself to light up the wonderful world.

Perfect one-stop outdoor lighting solution service provided, including lighting design consultant, lighting selection, lighting production, transportation assistance,installation instructions, after sales service, etc. Solve problem, reduce cost in after sales.

Living Room Chandelier

Iron Chandelier,Mid Century Chandelier,Hanging Chandelier,Modern Chandelier Lights

GUANGDONG LAVIUS LIGHTING CO., LTD. , https://www.laviuslighting.com